FLUKE 70 III CALIBRATION and FLUKE 70 III REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 70 III Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 70 III   Description / Specification:    
FLUKE 70 III Handheld Analog / Digital Multimeter

The Fluke 70 III Analog/Digital Multimeter is suitable for measurements in protected circuits, which do not exceed 4800 VA. It defaults to autorange when first turned on, manual ranging is available in V ac, V dc, ohms, A ac, and A dc. Specifications. VDC Ranges: 320.0 mV, 3.200 V, 32.00 V, 320.0 V, 600 V. VDC Best Accuracy: ±(0.3%+ 1) @ 320.0 mV, 3.200 V, 32.00 V, 320.0 V ranges. VAC Ranges (45 to 500 Hz, 3.2V range. Other ranges 45 to 1 kHz): 3.200 V, 32.00 V, 320.0 V, 600 V. VAC Best Accuracy: ±(2%+ 2), all ranges. Resistance Ranges: 320.0 ohm, 3200 ohm, 32.00 k-ohm, 320.0 k-ohm, 3.200 M-ohm, 32.00 M-ohm. Resistance Best Accuracy: ±(0.5%+1) @ 3200 ohm, 32.00 k-ohm, 320.0 k-ohm, 3.200 M-ohm ranges. Diode Range: 2.0 V. Display Digital: 3,200 counts, updates 2.5/sec. Display Analog: 31 segments, updates 25/sec.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 70 III. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your FLUKE 70 III CALIBRATION and/or FLUKE 70 III Handheld Analog / Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: